Content
Description
When upgrading Alteon images through WBM or Cyber Controller, the upload sometimes fails and returns the following error message: 406 Not Acceptable : ProcessMultipart: internal header too long
Affected Versions
33.0.18.0, 33.5.14.0, 34.0.10.0, 34.5.5.0 and later
Solution
Upgrade to one of the versions mentioned in ETA for fix.
Workaround
Upgrade from the CLI.
ETA for fix
The fix is scheduled to be available in the following releases:
- 33.0.20.0
- 33.5.16.0
- 34.0.12.0
- 34.5.7.0
- 35.0.0.0